Fat Extraction

The ANKOM XT10 Extractor is a lower cost semi-automated system with many of the features of the ANKOMXT15 Extractor at a lower cost. The ANKOMXT10 Extractor also accelerates the process by performing the extraction under pressure at elevated temperatures. It is capable of up to 15 extractions at a time and and is capable of a total throughput of more than 100 samples per day. Solvent recovery is done automatically at a rate of around 90%.

ANKOM XT10 Extractor

  • Automates the official crude fat procedure (AOCS Am 5-04)
  • Extract up to 15 samples at a time; capable of up to 100 samples per day
  • Reduces extraction time to under 40 minutes at 90°C
  • 97% Solvent recovery
  • Microprocessor controlled with LCD readout
  • Filter Bag Technology
  • Less bench space required
  • Fat ranges from 0% to 100%

The ANKOM XT15 Extractor advances and simplifies the conventional Soxhlet operation. It accelerates the process by performing the extraction under pressure at elevated temperatures. Capable of determining fats from 0% to 100%, the ANKOM XT15 Extractor allows extraction of up to 15 samples at a time and is capable of a total throughput of more than 150 samples per day. Solvent recovery and recycling is done automatically at a rate of 97% or greater.

ANKOM XT15 Extractor

  • Total automation of the official crude fat / solvent extraction (AOCS Am 5-04)
  • Extract up to 15 samples at a time; capable of up to 150 samples per day
  • Reduces extraction time to under 40 minutes at 90°C
  • No fume hood required Solvent Usage per Sample ~ 0.5 ml
  • 97% Solvent recovery
  • Microprocessor controlled with LCD readout
  • Solvent usage per sample ~ 0.5 ml
  • Filter Bag Technology
  • Less bench space required
  • No Vent-hood required
  • Fat ranges from 0% to 100%

The ANKOM HCl Hydrolysis System provides an easy method for perform the hydrolysis in total fat/oil analysis. It allows for batch hydrolysis of up to 15 samples at a time. Using Filter Bag Technology, total fat/oil hydrolysis is simplified. The technician inserts up to fifteen samples into the Teflon vessel, adds the acid solution and follows the system screen prompts. Once the program is selected, the system automatically completes the process and rinses the samples.

ANKOM HCl Hydrolysis System

  • Supports high-volume hydrolysis in total fat/oil analysis
  • Process up to 15 samples at a time
  • Filter Bag Technology
  • Includes ANKOMRD Dryer with acid neutralizing filter, H35 Blotter, & 100 XT4 bags
  • Microprocessor Controlled with LCD Readout
  • Closed system
  • Automatic rinse cycles
  • Less bench space required

Product Inquiry